In the discharged state, both the positive and negative plates become (PbSO 4), and the loses much of its dissolved and becomes primarily water. Negative plate reaction Pb(s) + HSO 4(aq) → PbSO 4(s) + H (aq) + 2e The release of two conduction electrons gives the lead electrode a negative charge. As electrons accumulate, they create an electric field which attracts hydrogen ions and repels s. [pdf]
A lead acid battery with 150 Ah capacity can theoretically provide a current of up to 150 amps for one hour. In practice, however, the battery will not be able to deliver this much current for more than a few minutes before the voltage starts dropping too low.
This comes to 167 watt-hours per kilogram of reactants, but in practice, a lead–acid cell gives only 30–40 watt-hours per kilogram of battery, due to the mass of the water and other constituent parts. In the fully-charged state, the negative plate consists of lead, and the positive plate is lead dioxide.
Lead batteries have a lower capacity if they are discharged faster. For example, a lead-acid battery can deliver 100Ah if it is discharged in 20 hours (C20=100), but if the same battery is discharged in 5 hours it will only deliver 70Ah (C5=70).
A typical lead–acid battery contains a mixture with varying concentrations of water and acid. Sulfuric acid has a higher density than water, which causes the acid formed at the plates during charging to flow downward and collect at the bottom of the battery.
The actual capacity of a lead acid battery, for example, depends on how fast you pull power out. The faster it is withdrawn the less efficient it is. For deep cycle batteries the standard Amp Hour rating is for 20 hours. The 20 hours is so the standard most battery labels don’t incorporate this data.
The lead–acid battery is a type of rechargeable battery first invented in 1859 by French physicist Gaston Planté. It is the first type of rechargeable battery ever created. Compared to modern rechargeable batteries, lead–acid batteries have relatively low energy density. Despite this, they are able to supply high surge currents.

How to maximize Lead Acid Battery Capacity1. Proper Charging Techniques Charging is a critical factor in maximizing lead acid battery capacity. The charging process needs to be carefully managed to avoid issues such as undercharging or overcharging. . 2. Equalization Charging . 3. Temperature Control . 4. Avoiding Deep Discharges . 5. Battery Sulfation Prevention . 6. Regular Maintenance and Inspection . [pdf]
Personally, I always make sure that anything connected to a lead acid battery is properly fused. The common rule of thumb is that a lead acid battery should not be discharged below 50% of capacity, or ideally not beyond 70% of capacity. This is because lead acid batteries age / wear out faster if you deep discharge them.
The common rule of thumb is that a lead acid battery should not be discharged below 50% of capacity, or ideally not beyond 70% of capacity. This is because lead acid batteries age / wear out faster if you deep discharge them. The most important lesson here is this:
The nominal capacity of sealed lead acid battery is calculated according to JIS C8702-1 Standard with using 20-hour discharge rate. For example, the capacity of WP5-12 battery is 5Ah, which means that when the battery is discharged with C20 rate, i.e., 0.25 amperes, the discharge time will be 20 hours.
It turns out that the usable capacity of a lead acid battery depends on the applied load. Therefore, the stated capacity is actually the capacity at a certain load that would deplete the battery in 20 hours. This is concept of the C-rate. 1C is the theoretical one hour discharge rate based on the capacity.
It's best to immediately charge a lead acid battery after a (partial) discharge to keep them from quickly deteriorating. A battery that is in a discharged state for a long time (many months) will probably never recover or ever be usable again even if it was new and/or hasn't been used much.
A battery at 10.5 - 10.8 volts at rest is probably damaged. A lead acid battery should never be below 11.80 volt at rest. ↩ 'bad' battery protection solutions will just start to oscillate as the battery voltage recovers (above the cut-off threshold) when the load is removed.

A deep-cycle battery is a battery designed to be regularly deeply discharged using most of its capacity. The term is traditionally mainly used for in the same form factor as ; and contrasted with starter or cranking automotive batteries designed to deliver only a small part of their capacity in a short, high-current burst for starting an engine. A deep-cycle battery will have depth of discharge greater than 50%, and may go as high as 80%. [pdf]
To prevent damage while discharging a lead acid battery, it is essential to adhere to recommended discharge levels, monitor the battery’s temperature, maintain proper connections, and ensure consistent maintenance. Recommended discharge levels: Lead acid batteries should not be discharged below 50% of their total capacity.
Specific actions and conditions can contribute to the premature discharge of a lead acid battery. For example, frequent deep discharges, prolonged storage in a discharged state, or operation in extreme temperatures can exacerbate the sulfation process. Regular maintenance and following guidelines for discharge levels are vital.
By understanding and implementing these practices, users can effectively prevent damage while discharging a lead acid battery and ensure its reliable performance. Discharging a lead acid battery too deeply can reduce its lifespan. For best results, do not go below 50% depth of discharge (DOD).
Personally, I always make sure that anything connected to a lead acid battery is properly fused. The common rule of thumb is that a lead acid battery should not be discharged below 50% of capacity, or ideally not beyond 70% of capacity. This is because lead acid batteries age / wear out faster if you deep discharge them.
It's best to immediately charge a lead acid battery after a (partial) discharge to keep them from quickly deteriorating. A battery that is in a discharged state for a long time (many months) will probably never recover or ever be usable again even if it was new and/or hasn't been used much.
A deep-cycle lead acid battery should be able to maintain a cycle life of more than 1,000 even at DOD over 50%. Figure: Relationship between battery capacity, depth of discharge and cycle life for a shallow-cycle battery. In addition to the DOD, the charging regime also plays an important part in determining battery lifetime.
We are deeply committed to excellence in all our endeavors.
Since we maintain control over our products, our customers can be assured of nothing but the best quality at all times.